PLASTICIZED GRANULES FOR INSULATION OF ELECTRICAL CABLES

Plasticized granules for electrical cables are recommended for general purpose insulation and sheeting or with special properties such as high flame retardance, resistance of low temperature, high temperature etc.

Appearance, shape, sizes and colour of granules :

The granules have an homogenous appearance, cylindrical or lenticular shape, sizes up to max. 5 mm (max. 4% granules above the limit or agglomerated are acceptable). The granules can be natural or coloured as customer's requirement.

Packing :

The granules are packed in polyethylene bags of 30 kgs, in polyethylene bags repacked in polypropylene bags of 30 kgs or big bags of 750 kgs.

Storage and transport of granules :

The granules are stored in closed, dry warehouses, far away of direct UV action, at a distance of minimum 2 m from any heating source; the storage temperature is recommended to be from +50C up to +400C.
The granules must be kept min. 24 hours at room temperature before the processing.
The transport of granules is done by covered means of transport.

Technical properties of granules :

Tehnical properties of granules are shown in the tables. The values shown in the tables are the result of tests made on specimens, got in conformity with test methods, specific to each characteristic; these values are not the values of the characteristics got on finished product, obtained from granules.
Connections can be done with international standards (DINVDE 0207, GOST 5960) at customer's requirement.

Types

I 80

I 88

I 88-13

IF*

I2

Applications

General purpose insulation
up to 1 KV

Flame retardant
insulation up to 1 KV

Insulation for power
cables up to 6 KV

Technical characteristics

UM

Test method

Values

Density

g/cm3

STAS 5886

1,25-1,35

1,25-1,35

-

1,30-1,40

1,31-1,41

ISOR 1183

-

-

1,25-1,35

-

-

Hardness at 23+20C

0ShA

STAS 8643

78+4

87+4

-

91+4

-

ASTMD 2240

-

-

88+3

-

-

Thermal stability at 1800C

minutes

BS 2782 met 130A

min 150

min 150

-

-

-

Thermal stability at 2000C

-

-

min 100

min 100

min 150

Tensile strength

N/mm2

STAS 6642

min 14

min 18

-

min 20

min 15

ASTMD 638

-

-

min 17

-

-

Elongation at break

%

STAS 6642

min 250

min 220

-

min 200

min 150

ASTMD 638

-

-

min 200

-

-

Low temperature resistance

0C

STAS 7014

-30

-30

-

-20

-

ASTMD 746

-

-

-20

-

-

Volume resistivity at 230C

Ohmcm

STAS 6107

min 1*1013

min 2*1013

-

min 1*1014

-

DIN 53482

-

-

min 2*1013

-

-

Dielectric strength

KV/mm

STAS 6257

min 20

min 20

-

min 20

min 25

ASTMD 179

-

-

min 19

-

-

Inflammability

seconds

STAS 7015

max 60

max 60

max 60

max 30

max 60

* Type IF is also manufactured to have resistance in humid and dry climate conditions (climate protection T, 1 working category, in conformity with SF 1/94)
 

Types

I2F

I3

I4

I5

IM 80-13

Applications

Flame retardant cables
insulation up to 6 KV

Flame retardant cables
insulation up to 10 KV

Insulation of flexibile cables
up to 1 KV

Technical characteristics

UM

Test method

Values

Density

g/cm3

STAS 5886

1,31-1,41

1,35-1,45

1,20-1,30

-

-

ISOR 1183

-

-

-

-

1,25-1,35

Hardness at 23+20C

0ShA

STAS 8643

91+4

92+4

78+4

80+4

-

ASTMD 2240

-

-

-

-

-

Thermal stability at 1800C

minutes

BS 2782 met 130A

-

-

-

-

-

Thermal stability at 2000C

150

150

90

60

100

Tensile strength

N/mm2

STAS 6642

min 18

min 15

min 15

min 18

-

ASTMD 638

-

-

-

-

min 15

Elongation at break

%

STAS 6642

min 180

min 150

min 280

min 250

-

ASTMD 638

-

-

-

-

min 275

Low temperature resistance

0C

STAS 7014

-20

-20

-40

-

-

ASTMD 746

-

-

-

-

-20

Volume resistivity at 230C

Ohmcm

STAS 6107

-

-

min 1*1012

min 1*1013

-

DIN 53482

-

-

-

-

min 1*1013

Dielectric strength

KV/mm

STAS 6257

min 25

min 25

min 20

min 20

-

ASTMD 179

-

-

-

-

min 20

Inflammability

seconds

STAS 7015

max 30

max 60

max 60

max 60

max 60


 

Types

IM 85-13

F

I6

I 88-14

I 105

Applications

Insulation and sheeting
of flexibile cables
up to 1 KV

Insulation of telephonic
cables up to 1 KV

Insulation of cables
with continuous working
temperature of 1050C

Technical characteristics

UM

Test method

Values

Density

g/cm3

STAS 5886

-

1,20-1,30

1,35-1,45

-

1,25-1,35

ISOR 1183

1,25-1,35

-

-

1,25-1,35

-

Hardness at 23+20C

0ShA

STAS 8643

-

73+4

88+4

-

89+4

ASTMD 2240

85+3

-

-

88+3

-

Thermal stability at 1800C

minutes

BS 2782 met 130A

-

min 100

min 100

-

min 150

Thermal stability at 2000C

min 100

-

-

min 100

-

Tensile strength

N/mm2

STAS 6642

-

min 14

min 18

-

min 18

ASTMD 638

min 17

-

-

min 18

-

Elongation at break

%

STAS 6642

-

min 250

min 180

-

min 200

ASTMD 638

min 250

-

-

min 250

-

Low temperature resistance

0C

STAS 7014

-

-30

-20

-

-20

ASTMD 746

-20

-

-

-20

-

Volume resistivity at 230C

Ohmcm

STAS 6107

-

min 1*1011

min 1*1014

-

min 1*1013

DIN 53482

min 2*1013

-

-

min 1*1014

-

Dielectric strength

KV/mm

STAS 6257

-

min 15

min 20

-

min 20

ASTMD 179

min 20

-

-

min 20

-

Inflammability

seconds

STAS 7015

max 60

max 60

max 60

max 60

max 60


 

Types

M 75

M 80

M 1

M 85

M 2

Applications

General purpose sheeting

Sheeting resistant at bad
climate conditions

Technical characteristics

UM

Test method

Values

Density

g/cm3

STAS 5886

-

-

1,25-1,40

-

1,25-1,40

ISOR 1183

1,25-1,35

1,25-1,35

-

1,25-1,35

-

Hardness at 23+20C

0ShA

STAS 8643

-

-

84+4

-

87+4

ASTMD 2240

75+3

80+3

-

85+3

-

Thermal stability at 1800C

minutes

BS 2782 met 130A

-

-

min 100

-

-

Thermal stability at 2000C

min 80

min 60

-

min 60

min 60

Tensile strength

N/mm2

STAS 6642

-

-

min 17,5

-

min 17,5

ASTMD 638

min 16

min 17

-

min 15

-

Elongation at break

%

STAS 6642

-

-

min 250

-

min 225

ASTMD 638

min 300

min 280

-

min 260

-

Low temperature resistance

0C

STAS 7014

-

-

-30

-

-25

ASTMD 746

-25

-18

-

-18

-

Dielectric strength

KV/mm

STAS 6257

-

-

min 20

-

min 20

ASTMD 179

min 20

min 20

-

min 20

-

Loss of plasticizer

%

STAS 5690 met A

-

-

max 3

-

max 3

Inflammability

seconds

STAS 7015

max 60

max 60

max 60

max 60

max 60


 

Types

M 3

M 70

M 50

M 50 F

M F *

FRSI - 90

Applications

Sheeting for very
flexible protection

Low
temperature
resistant
sheeting

Low temperature
resistant and flame
retardant sheeting

Cable sheeting
for working
temperature of
900C

Technical characteristics

UM

Test method

Values

Density

g/cm3

STAS 5886

1,20-1,30

-

1,20-1,30

1,20-1,30

1,25-1,33

1,25-1,35

ISOR 1183

-

1,25-1,35

-

-

-

-

Hardness at 23+20C

0ShA

STAS 8643

68+4

-

77+4

77+4

88+4

90+5

ASTMD 2240

-

70+3

-

-

-

-

Thermal stability at 1800C

minutes

BS 2782 met 130A

min 100

-

min 120

min 120

-

-

Thermal stability at 2000C

-

min 50

-

-

min 100

min 100

Tensile strength

N/mm2

STAS 6642

min 14

-

min 15

min 15

min 17,5

min 17,5

ASTMD 638

-

min 10

-

-

-

-

Elongation at break

%

STAS 6642

min 280

-

min 300

min 300

min 250

min 250

ASTMD 638

-

min 320

-

-

-

-

Low temperature resistance

0C

STAS 7014

-40

-

-50

-50

-30

-30

ASTMD 746

-

-30

-

-

-

-

Dielectric strength

KV/mm

STAS 6257

min 15

-

min 20

min 20

min 20

min 20

ASTMD 179

-

min 18

-

-

-

-

Loss of plasticizer

%

STAS 5690 met A

max 3

-

max 4

max 4

max 3

-

mg/cm2

STAS 11388/11

-

-

-

-

-

max 1,5

Inflammability

seconds

STAS 7015

max 60

max 60

max 60

max 30

max 30

-

Oxigen index

%

STAS 12321

-

-

-

-

-

min 28

* Type MF is also manufactured to have resistance in humid and dry climate conditions (climate protection T, 1 working category, in conformity with SF 1/94)
 